 TRUMPower
D E SCR IPTION
Comprising single and multiple output models with 200 watts of continuous output power, the TM200 series is specially designed for medical applications. Auto-ranging input allows them to operate from any line voltage throughout the world without a selector strap. All auxiliary outputs are with magnetic amplifier or linear regulator to keep regulation. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking. A cover-and-fan assembly can be added during manufacturing.
200 WATT MEDICAL POWER SUPPLIES
TM200 SERIES
(MDD)
Saf et y Sta n da rd A ppr o va ls: F EATU R E S
Low safety ground leakage current M e e t E N 5 5 0 11 a n d F C C c l a s s B Auto-ranging input Short-circuit protection with auto-recovery Pow er Fail Detect PFD signal 100% burn-in at full rated load Optional cover-and-fan assembly
UL 2601-1 CSA C22.2 No. 601.1 TUV EN60601-1
IN PUT S PE C IF ICAT ION S
I n p u t v o l ta g e : Input frequency: Input current: Leakage current: 9 0 t o 1 3 0 VA C , o r 1 8 0 t o 2 6 4 VA C a u t o - r a n g i n g 47 to 63 Hz 4 . 5 A r m s f o r 11 5 VA C 2 . 6 A r m s f o r 2 3 0 VA C 9 0 A m a x . @ 11 5 VA C , 6 0 H z 1 5 A m a x . @ 2 3 0 VA C , 5 0 H z
E N V IR O N M ENTA L SP E C IF ICATI O N S
Operating temperature: Storage temperature: Relative humidity: Derating: Cooling: 0C to +70C -40C to +85C 5% to 95% non-condensing Derate from 100% at +50C linearly to 50% at +70C 2 5 C F M f o r c e d a i r, p r o v i d e d on covered version, to be provided f o r U - b r a c k e t version by user
OUTPUT SPECIFICATIONS
Output voltage/current See rating chart Total output power Ripple and noise 200 watts maximum 2% peak to peak maximum
GENERAL SPECIFICATIONS
64KHz 5KHz 70% minimum on all models 12 msec minimum at 110VAC 0.5% maximum at full load 20 amps @ 115VAC, or 40 amps @ 230VAC, at 25C cold start Withstand voltage 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF 450,000 hours at full load at 25C ambient, calculated per MIL-HDBK-217F EMC Performance (EN60601-1-2: 2 0 0 1 ) E N 5 5 0 11 : Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, 8KV air and 4KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, 1KV EN61000-4-5: Surge, 1KV diff, 2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 1A/m E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms and >95% reduction for 10ms Interruptions, >95% for 5000ms Switching frequency Efficiency Hold-up time Line regulation Inrush current
Overvoltage protection Provided on output #1 only; set at 112 - 132% of its nominal output voltage Overcurrent protection All outputs protected to short circuit conditions Temperature coefficientAll outputs 0.04%/C maximum Transient response Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500s after a 25% step load change TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1 ms prior to +5V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after +5V is within regulation.
PFD signal
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
Product No. TM200-S05 TM200-S12 TM200-S15 TM200-S24 TM200-S30 TM200-S48 TM200-D23 TM200-D24 TM200-D25 TM200-T30 TM200-T31 TM200-T32 TM200-T33 TM200-Q40 TM200-Q41 TM200-Q42 TM200-Q44 TM200-Q45 Notes: Vnom. 5V 12V 15V 24V 30V 48V +5V +5V +5V +5V +5V +5V +5V +5V +5V +5V +5V +5V Output #1 Imin. Imax. Tol. 3.0A 40A 2% 1.2A 16.7A 2% 1.0A 13.4A 2% 0.6A 8.4A 2% 0.5A 6.7A 2% 0.5A 4.2A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% 3.0A 30A 2% Output #2 Vnom. Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) +12V 0A 8A +15V 0A 6A +24V 0A 4A +12V 0A 8A +12V 0A 8A +15V 0A 6A +15V 0A 6A +12V 0A 8A +15V 0A 6A +12V 0A 8A +12V 0A 8A +12V 0A 8A Tol. Output #3 Vnom. Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) -5V 0A 6A -12V 0A 4A -15V 0A 4A -12V 0A 4A -12V 0A 4A -15V 0A 4A -12V 0A 4A -15V 0A 4A -12V 0A 4A Tol.
TM200 SERIES
Output #4 Vnom. Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 5V 0A 6A 24V 0A 4A 12V 0A 4A 15V 0A 4A 24V 0A 4A Maximum Output Power 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W 200W
Tol.
4% 4% 4% 4% 4% 4% 4% 4% 4% 4% 4% 4%
4% 4% 4% 4% 4% 4% 4% 4% 4%
4% 4% 4% 4% 4%
(1) Add suffix "C" for enclosed format, e.g. TM200-Q45C. (2) Peak current is 12A on +12V, 9A on +15V and 6A on +24V. (3) Output #4 is floating. It can be connected externally for positive or negative output. (4) 200 watts for "C" version with a cover-and-fan assembly. 150 watts U-bracket version without moving air (maximum current of output #1 & #2 derated to 70%), or 200 watts with 25 CFM forced air provided by user. (5) When the remote sense facility is not used, +Sense must be connected to +V, and -Sense to return, on P2 connector. (6) All models may be operated at no-load. At no-load, output voltage tolerance increases to 10%
MECHANICAL SPECIFICATIONS
NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Beau Inc. P/N 72-5-03C, output connector P2 is Beau Inc. P/N 72-5-09C. Screws are #6-32 on 0.375 inch centers. 4. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal. 5. Connector P4 mates with Molex housing 22-01-1023 and Molex 40445 series crimp terminal. 6. P4 is for DC fan rated 24V/0.12A (models TM200-S24, -S30, -D25), or 12V/0.2A (other models) 7. Weight: 1.40 Kgs (3.08Lbs.) approx. for U-bracket version 1.60 Kgs (3.52 Lbs.) approx. for "C" version
PIN CHART
CON Product No. TM200-S05 TM200-S15 TM200-S30 TM200-D23 TM200-D25 TM200-T30 TM200-T32 TM200-Q40 TM200-Q42 TM200-Q45 PIN 1 P1 2 3 1, 2 3, 4, 5 RET. 6 P2 7 8 9 1 FAN FAN FAN FAN 2 COM. RET. COM. RET. COM. RET. COM. RET. P3 3 COM. RET. COM. RET. COM. RET. COM. RET. 4 PFD PFD PFD PFD
TM200-S12 AC TM200-S24 LIVE TM200-S48 TM200-D24 AC LIVE TM200-T31 AC TM200-T33 LIVE TM200-Q41 AC TM200-Q44 LIVE
AC AC -SENSE NEUTRAL GROUND
OUTPUT OUTPUT OUTPUT +SENSE #1 #1 #1 N.C. N.C. N.C. N.C.
AC AC OUTPUT COM. OUTPUT N.C. NEUTRAL GROUND #1 RET. #2 AC AC OUTPUT COM. OUTPUT OUTPUT NEUTRAL GROUND #1 RET. #2 #3 AC AC OUTPUT COM. OUTPUT OUTPUT NEUTRAL GROUND #1 RET. #2 #3
OUTPUT OUTPUT #4 #4 RETURN
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com